Skip to content

Front Matter 1: Cover Letter to Samuel Insull

Research workbench, not a finished commentary page.

This page is generated from processed source text and candidate catalogs. It exists to help researchers decide what to verify, promote, and deeply decode next.

FieldValue
SourceInvestigation of Some Trouble in the Generating System of the Commonwealth Edison Co.
Year1919
Section IDcommonwealth-edison-generating-system-trouble-front-letter-01
LocationPDF pages 1-7, lines 1-144
Statuspdf-text-extracted-candidate
Word Count625
Equation Candidates In Section0
Figure Candidates In Section0
Quote Candidates In Section1
[[PDF_PAGE:1]] FOR PRIVATE CIRCULATION ONLY Investigation of some Trouble in the Generating System of the Commonwealth Edison Co. Chicago 1919 Charles P. Steinmetz, A. M., Ph. D. [[END_PDF_PAGE:1]] [[PDF_PAGE:2]] [[END_PDF_PAGE:2]] [[PDF_PAGE:3]] Investigation of some Trouble in the Generating System of the Commonwealth Edison Co. Chicago 1919 Charles P. Steinmetz, A. M., Ph. D. [[END_PDF_PAGE:3]] [[PDF_PAGE:4]] COPYRIGHT 1910 CHARLES P. STEINMETZ [[END_PDF_PAGE:4]] [[PDF_PAGE:5]] Schenectady, N. Y., December 19, 1919. Mr. S. Insull, Pres. Commonwealth Edison Company, Chicago, 111. My dear Mr. Insull: Enclosed I send you report of investigation of. some operating trou- bles in the generating system of the Commonwealth Edison Company, during 1919, with some recommendations. I am sending copies of the report to Mr. L. Ferguson and to Mr. R. F. Schuchardt. I regret that in some respects the report is not as
... ors, which would not interfere with the economic use of tie cables of substation feeder cables. 2.) The substations were originally operated by separate feeders, but the need of using the feeder cables and apparatus in the most eco- nomical manner has led to tying substations together on the same feeder, which necessarily increases the interference between substations and between generating stations in case of trouble, and further changes are contemplated and desirable. It therefore appears advisable to make a thorough study of substation operation with the v ...
... recommendations. I am sending copies of the report to Mr. L. Ferguson and to Mr. R. F. Schuchardt. I regret that in some respects the report is not as final and conclusive as I like to see it, but during the years of successful operation since the installation of the protective reactances, your system has grown and changed so much, and while I have received very complete and extremely satis- factory information and data from your engineers, it necessarily is not possible for me to be as fully familiar with the system, as I was once, but I hope that I shall now b ...
Concept CandidateHits In SectionStatus
Tie cable2pdf-text-extracted-candidate
Power limiting reactor1pdf-text-extracted-candidate
Protective reactance1pdf-text-extracted-candidate
Term CandidateHits In SectionStatus
tie cable2pdf-text-extracted-candidate
power limiting reactor1pdf-text-extracted-candidate
protective reactance1pdf-text-extracted-candidate
Candidate IDOCR / PDF-Text CandidateSource Location
No chapter-local candidates yet--
Candidate IDOCR / PDF-Text CandidateSource Location
No chapter-local candidates yet--
Candidate IDCandidate PassageSource Location
commonwealth-edison-generating-system-trouble-quote-scaled-system-modellines 121-132
  • Ether references: Verify exact wording before drawing conclusions. Ether language must be separated from later interpretive systems.
  • Impedance / reactance: Translate historical opposition terms into modern impedance, admittance, conductance, susceptance, and complex-plane notation.
  • Ether references: If Steinmetz mentions ether, quote only the verified source words first; any broader ether-field synthesis belongs in a labeled interpretive layer.
  1. Open the full source text and the scan or raw PDF.
  2. Verify the chapter boundary and surrounding context.
  3. Promote exact quotations only after checking the source image.
  4. Move mathematical candidates into canonical equation pages only after formula typography is corrected.
  5. Move diagram candidates into the diagram archive only after image extraction, crop verification, and manifest creation.
  6. Keep Steinmetz wording, modern translation, and ether-field interpretation in separate labeled layers.