Apparatus Section 7: Synchronous Converters: Variable Ratio Converters ("split Pole" Converters)

Research workbench, not a finished commentary page.

This page is generated from processed source text and candidate catalogs. It exists to help researchers decide what to verify, promote, and deeply decode next.

FieldValue
SourceTheoretical Elements of Electrical Engineering
Year1915
Section IDtheoretical-elements-electrical-engineering-section-86
Locationlines 15586-15734
Statuscandidate
Word Count1144
Equation Candidates In Section0
Figure Candidates In Section0
Quote Candidates In Section0
VII. Variable Ratio Converters ("Split Pole" Converters) 98. With a sine wave of alternating voltage, and the com- mutator brushes set at the magnetic neutral, that is, at right angles to the resultant magnetic flux, the direct voltage of a SYNCHRONOUS CONVERTERS 253 converter is constant at constant impressed alternating voltage. It equals the maximum value of the alternating voltage between two diametrically opposite points of the commutator, or "dia- metrical voltage," and the diametrical voltage is twice the voltage between alternating lead and neutral, or star or Y voltage of the polyphase system. A change of the direct voltage, at constant impressed alter- nating voltage, can be produced — Either by changing the position angle between the commu- tator brushes and the resultant magnetic flux, so that the direct voltage between the brushes is
... ned in the so-called " Regulating Pole Converter" or "Split Pole Converter," which is used to supply, from constant alternating voltage supply, direct voltage varying sometimes over a range of ± 20 per cent. In this type of converter, the field pole is divided into sections, usually two, a smaller one, the regulating pole, and a larger one, the main pole. By varying the excitation of the regulating pole from maximum in one direction, to maximum in the opposite direction, the dir ...
VII. Variable Ratio Converters ("Split Pole" Converters) 98. With a sine wave of alternating voltage, and the com- mutator brushes set at the magnetic neutral, that is, at right angles to the resultant magnetic flux, the direct voltage of a SYNCHRONOUS CONVERTERS 253 converter is constant at constant impressed alternating voltage. It equals the maximum value of the alternating volta ...
VII. Variable Ratio Converters ("Split Pole" Converters) 98. With a sine wave of alternating voltage, and the com- mutator brushes set at the magnetic neutral, that is, at right angles to the resultant magnetic flux, the direct voltage of a SYNCHRONOUS CONVERTERS 253 converter is constant at constant impressed ...
... time, lagging current, it is occasionally preferable to start it from the direct-current side as direct-current motor. This can be done when connected to storage battery or direct-current generator. When feeding into a direct-current system together with other converters or con- verter stations, all but the first converter can be started from the continuous current side by means of rheostats inserted into the armature circuit. To avoid the necessity of synchronizing the converter, by p ...
Concept CandidateHits In SectionStatus
Ether1seeded
Light1seeded
Term CandidateHits In SectionStatus
ether1seeded
Candidate IDOCR / PDF-Text CandidateSource Location
No chapter-local candidates yet--
Candidate IDOCR / PDF-Text CandidateSource Location
No chapter-local candidates yet--
Candidate IDCandidate PassageSource Location
No chapter-local candidates yet--
  • Field language: Read for whether field language is mechanical, geometrical, causal, descriptive, or simply a convenient engineering model.
  • Magnetism: Track flux, reluctance, permeability, magnetizing force, and loss language against modern magnetic-circuit terminology.
  • Waves / transmission lines: Map Steinmetz’s wave and line language onto modern distributed constants, propagation velocity, standing waves, and reflections.
  • Ether references: Verify exact wording before drawing conclusions. Ether language must be separated from later interpretive systems.
  • Hysteresis: Compare the passage with modern magnetic loss, B-H loop area, lag, material memory, and empirical loss laws.
  • Field language: Field-pressure or field-gradient interpretations can be explored here only after the explicit source passage and modern engineering translation are kept distinct.
  • Magnetism: Centrifugal/divergent magnetic-field readings are interpretive overlays, not automatic historical claims.
  • Waves / transmission lines: Standing/traveling wave passages may support richer field interpretations; the page keeps those readings separate from verified Steinmetz wording.
  • Ether references: If Steinmetz mentions ether, quote only the verified source words first; any broader ether-field synthesis belongs in a labeled interpretive layer.
  • Hysteresis: An interpretive reading can treat hysteresis as field lag or memory, but the historical claim must remain Steinmetz’s actual magnetic-loss treatment.
  1. Open the full source text and the scan or raw PDF.
  2. Verify the chapter boundary and surrounding context.
  3. Promote exact quotations only after checking the source image.
  4. Move mathematical candidates into canonical equation pages only after formula typography is corrected.
  5. Move diagram candidates into the diagram archive only after image extraction, crop verification, and manifest creation.
  6. Keep Steinmetz wording, modern translation, and ether-field interpretation in separate labeled layers.